Sub topic 11
Gain-bandwidth product and closed-loop bandwidth
This chapter assumes you know the ideal inverting and non-inverting gain equations, the virtual short, and decibels. It also assumes you have seen the gain error caused by finite open-loop gain. Here we add frequency: a real op amp's open-loop gain falls as frequency rises, and that limits how much bandwidth a closed-loop amplifier has.
The open-loop gain rolls off
A general-purpose op amp is internally compensated. Its open-loop gain A(f) is large at DC, for example 100,000 (100 dB). It starts to fall at a low frequency called the dominant pole, often 5 to 10 Hz. Above that pole, A(f) drops by 20 dB per decade, so gain times frequency stays constant:
A(f) ≈ GBW / f
GBW is the gain-bandwidth product. It is the frequency at which the open-loop gain reaches 1 (0 dB), called the unity-gain frequency. A part with a GBW of 1 MHz has A = 1 at 1 MHz, A = 10 at 100 kHz, and A = 100,000 at 10 Hz.
Closed-loop bandwidth
Feedback holds the closed-loop gain at its ideal value only while the loop gain, A·β, is much larger than 1. The feedback fraction β is the part of the output returned to the inverting input:
- Non-inverting amplifier: β = Rg / (Rf + Rg), so the ideal gain is 1/β.
- Inverting amplifier: the noise gain is 1 + Rf/Rin, which is also 1/β.
The closed-loop gain begins to fall where A(f) = 1/β. Setting GBW / f = 1/β gives the closed-loop bandwidth:
f(−3 dB) ≈ GBW · β = GBW / (noise gain)
For the non-inverting amplifier, the noise gain equals the signal gain, so bandwidth is GBW divided by gain. For the inverting amplifier, the noise gain is the signal gain magnitude plus 1.
| Configuration | Signal gain | Noise gain | Bandwidth with GBW = 1 MHz |
|---|---|---|---|
| Non-inverting, Rf = 9 kΩ, Rg = 1 kΩ | +10 | 10 | 100 kHz |
| Inverting, Rf = 10 kΩ, Rin = 1 kΩ | −10 | 11 | about 91 kHz |
| Voltage follower | +1 | 1 | 1 MHz |
The follower has the widest bandwidth because it has the lowest noise gain.
The curve that falls steadily is the open-loop gain. The flat curve is a closed loop with a gain of 10 (20 dB). It stays flat until it meets the open-loop curve near 100 kHz. The chart is approximate: the real −3 dB point lies slightly below the intersection.
Design consequences
Bandwidth and gain trade against each other. A gain of 100 with a 1 MHz op amp gives only about 10 kHz. If you need 100 kHz at a gain of 100, you need an op amp with a GBW of at least 10 MHz, and preferably more for margin.
The same effect adds gain error before the −3 dB point. At a frequency f, the open-loop gain is about GBW / f. The loop gain is therefore GBW·β / f, and the gain error is roughly f / (GBW·β). At one tenth of the closed-loop bandwidth, the error is already about 10%, much larger than the 0.01% DC error from A = 100,000.
import math
def closed_loop_bandwidth(gbw_hz, noise_gain):
return gbw_hz / noise_gain
def gain_magnitude(f_hz, ideal_gain, gbw_hz, noise_gain):
fc = closed_loop_bandwidth(gbw_hz, noise_gain)
return abs(ideal_gain) / math.sqrt(1 + (f_hz / fc) ** 2)
gbw = 1e6
print(closed_loop_bandwidth(gbw, 10)) # 100000.0
print(closed_loop_bandwidth(gbw, 11)) # about 90909
print(gain_magnitude(10e3, 10, gbw, 10)) # about 9.95
print(gain_magnitude(100e3, 10, gbw, 10)) # about 7.07The second print shows the inverting bandwidth. The last line confirms that the gain is 3 dB down (10 / √2 ≈ 7.07) at 100 kHz.
Exercise
An op amp has GBW = 5 MHz. You build a non-inverting amplifier with Rf = 49 kΩ and Rg = 1 kΩ. What is the approximate closed-loop bandwidth, and what is it if you change it to an inverting amplifier with the same gain magnitude using Rf = 49 kΩ and Rin = 1 kΩ?
Show answer
The non-inverting gain is 1 + 49 = 50, so the noise gain is 50 and the bandwidth is 5 MHz / 50 = 100 kHz. The inverting amplifier has gain −49 and noise gain 1 + 49 = 50, so its bandwidth is also 100 kHz. The two match here because both use the same Rf and the same resistor to ground or source, so the feedback fraction is the same.