Sub topic 14
Real inductors and their limits
This chapter assumes you know the ideal law v = L di/dt, the energy formula (1/2) L i², and how a series RL circuit behaves at DC and during switching. Here you will see where the ideal model fails and how to read a datasheet so you can pick a part that works.
From ideal to real
The ideal inductor has one property: inductance L. It has no resistance and no capacitance. Its current can grow without limit and its energy storage is unlimited. A real coil of wire has none of those properties. Three effects matter most in practice:
- Winding resistance, because copper is not a perfect conductor.
- Parasitic capacitance, because neighboring turns of wire act like capacitor plates.
- Saturation, because a magnetic core can hold only a limited amount of magnetic flux.
The following sections take each effect in turn and then show how they combine in a datasheet.
Winding resistance
A wire of length ℓ, cross-section area A, and resistivity ρ has resistance R = ρℓ/A. A coil with many turns needs a lot of wire, so it always has some resistance. A common model puts a resistor R_dc in series with the ideal inductor.
This series resistance has three consequences:
- At DC steady state, the inductor is no longer a perfect short circuit. It acts as a small resistor, so the final current is V/(R + R_dc), not V/R.
- Power is lost as heat. The loss is I²R_dc, and it limits how much current the part can carry continuously.
- The time constant of an RL circuit becomes L/(R + R_dc).
The example below compares an ideal inductor with one that has 5 Ω of winding resistance. It uses the same 12 V source, 100 Ω resistor, and 500 mH inductor as the RL step response earlier in this tutorial.
import math
V = 12.0 # source voltage in volts
R = 100.0 # external resistance in ohms
L = 0.5 # inductance in henries
R_dc = 5.0 # winding resistance in ohms
for label, r_total in (("ideal", R), ("real", R + R_dc)):
tau = L / r_total
i_final = V / r_total
print(f"{label}: tau = {tau * 1000:.2f} ms, final current = {i_final * 1000:.1f} mA")
i_ideal_loss = (V / R) ** 2 * 0
i_loss = (V / (R + R_dc)) ** 2 * R_dc
print(f"power lost in winding at DC: {i_loss * 1000:.1f} mW")The ideal case gives τ = 5.00 ms and 120.0 mA. The real case gives τ = 4.76 ms and 114.3 mA, with about 65.3 mW lost in the winding. A 5 Ω error looks small here because the external resistor is large. In a low-voltage power converter, where the load resistance may be under 1 Ω, winding resistance can dominate.
Parasitic capacitance
Each pair of adjacent turns has a small capacitance between them, because they are conductors separated by thin insulation. The sum of these effects behaves like one capacitor C_p connected across the whole coil. Typical values run from a few picofarads for a small air-core coil to hundreds of picofarads for a large, tightly wound one.
A better model of a real inductor is therefore an ideal inductor L in series with Rdc, with Cp in parallel across both.
Self-resonant frequency
The inductor and Cp form a parallel resonant circuit. Ignoring Rdc, the resonance occurs at the self-resonant frequency:
fSRF = 1 / (2π √(L Cp))
Below fSRF, the part behaves as an inductor. Its impedance rises with frequency, as jωL predicts. Near fSRF, the impedance peaks sharply. Above f_SRF, the capacitance dominates and the part behaves as a capacitor. An inductor used above its self-resonant frequency does not do its job.
import math
L = 10e-6 # 10 uH
C_p = 5e-12 # 5 pF parasitic capacitance
f_srf = 1 / (2 * math.pi * math.sqrt(L * C_p))
print(f"self-resonant frequency: {f_srf / 1e6:.1f} MHz")This prints about 22.5 MHz. A common rule of thumb is to keep the operating frequency well below f_SRF, often a factor of 5 to 10 below, so the part stays inductive and its effective inductance does not drift.
Saturation
An inductor with a magnetic core has much higher inductance than the same coil in air, because the core concentrates magnetic flux. But a core material can carry only so much flux density. Once the core reaches its maximum, called saturation, additional current adds very little extra flux.
The effect on the circuit is severe. Inductance is the ratio of flux linkage to current, so when flux stops growing in proportion to current, the effective L falls sharply. Since di/dt = v/L, a smaller L lets the current climb much faster. The current can then rise out of control, limited only by the winding resistance and the source.
The ideal inductor never saturates, because it has no core model at all. Air-core inductors do not saturate either, but they provide far less inductance for the same size. Core materials differ in how they fail:
| Core type | Saturation behavior | Typical use |
|---|---|---|
| Air | No saturation, low inductance per volume | High-frequency RF circuits |
| Ferrite | Sharp saturation, low core loss at high frequency | Switching power supplies, filters |
| Powdered iron | Gradual (soft) saturation, higher loss | Power inductors with large current peaks |
| Laminated silicon steel | High flux capacity, high loss above a few kHz | Mains-frequency transformers and chokes |
Core loss
A core also dissipates energy when its flux alternates. Two mechanisms cause this loss. Hysteresis loss comes from the magnetic material not following the same path as flux rises and falls. Eddy-current loss comes from currents induced in the core itself. Both grow with frequency and with the size of the flux swing. Datasheet inductance and current ratings ignore this loss, but it adds to heating in real designs.
Reading a datasheet
Datasheets list several current ratings, and they mean different things. Choosing the wrong one is a common error.
| Parameter | What it means | What happens if you exceed it |
|---|---|---|
| L (at a stated frequency and current) | Nominal inductance, usually with a tolerance of ±10% to ±30% | Circuit timing or filter corner shifts |
| DCR | Winding resistance at DC | Higher loss and heating than expected |
| I_sat | Current at which L drops by a stated amount, often 20% or 30% | Inductance collapses, current spikes |
| I_rms (or I_heat) | Current at which the part warms by a stated amount, often 40 °C | Overheating, insulation damage |
| SRF | Self-resonant frequency | Part stops behaving as an inductor |
Use whichever of Isat and Irms is lower as your limit, and check the peak current, not only the average. In a switching converter, the peak inductor current is the average current plus half the ripple, and the peak is what saturates the core.
The following sketch estimates the peak current in a buck converter inductor and compares it with a rated saturation current.
V_in = 12.0 # input voltage in volts
V_out = 5.0 # output voltage in volts
L = 10e-6 # inductance in henries
f_sw = 500e3 # switching frequency in hertz
I_load = 2.0 # average load current in amperes
I_sat = 2.5 # rated saturation current in amperes
duty = V_out / V_in
ripple = (V_in - V_out) * duty / (L * f_sw) # peak-to-peak ripple in amperes
i_peak = I_load + ripple / 2
print(f"ripple = {ripple:.3f} A, peak = {i_peak:.3f} A")
print("safe" if i_peak < I_sat else "saturates")The ripple is about 0.817 A and the peak is about 2.408 A, so this part passes with 0.09 A of margin. That margin is thin. Inductance also falls with temperature and tolerance, so a designer would normally pick a part with more headroom.
Other practical limits
- Tolerance and drift: Inductance varies with manufacturing tolerance, temperature, and DC bias current. The datasheet value is measured under specific conditions that may not match your circuit.
- Stray magnetic fields: Open-core inductors radiate magnetic field that can couple into neighboring coils or traces. Shielded parts reduce this. This is the same coupling mechanism that a later chapter treats deliberately as mutual inductance.
- Interrupted current: A real inductor still resists sudden changes in current, so switching it off still creates a voltage spike. Parasitic capacitance and winding resistance only moderately limit the spike. A flyback diode or snubber is still needed.
Summary
A real inductor is an ideal inductor plus series resistance, parallel capacitance, core limits, and loss. Winding resistance reduces DC current and wastes power. Parasitic capacitance sets a self-resonant frequency above which the part stops acting as an inductor. Saturation makes inductance collapse when the current is too high. When choosing a part, check the peak current against I_sat, the RMS current against the heating rating, and the operating frequency against the SRF.
Exercise
A 22 µH inductor has 8 pF of parasitic capacitance, a saturation current of 3.0 A, and a heating current of 2.2 A. Your circuit carries 1.8 A average with 0.8 A peak-to-peak ripple at 300 kHz. Find the peak current and the self-resonant frequency. Is the part acceptable?
Show answer
Peak current = 1.8 + 0.8/2 = 2.2 A. That is below Isat (3.0 A). The RMS current is about 1.8 A (ripple adds very little), below the 2.2 A heating rating. fSRF = 1/(2π√(22e-6 × 8e-12)) = 1/(2π × 4.195e-9... ) ≈ 12.0 MHz. The operating frequency of 300 kHz is far below this, so the part stays inductive. The part is acceptable, though the 2.2 A peak equals the heating rating, so check the temperature rise at full load.
Exercise
A 100 mH inductor with 20 Ω winding resistance is connected through a switch to a 10 V source with no other resistance. What is the final DC current, and what is the time constant?
Show answer
The final current is V/Rdc = 10/20 = 0.5 A. The time constant is L/Rdc = 0.1/20 = 5 ms. An ideal inductor would give an unbounded current, so the winding resistance alone sets the limit.