Sub topic 13
Mesh analysis with dependent sources and supermeshes
This chapter assumes you can write KVL equations, solve a 2×2 linear system, and recognize the four controlled source types from earlier chapters.
The method
Mesh analysis assigns a clockwise current to each loop and applies KVL around it. Dependent sources add one step. Express the controlling variable in terms of the mesh currents before you substitute it.
- Label each mesh current.
- Write KVL for each mesh without a current source on its boundary.
- Replace each controlling variable with mesh currents.
- Solve the system.
Example 1: a dependent voltage source
Two meshes share a 4 Ω resistor. The left mesh has a 12 V source and a 2 Ω resistor. The right mesh has a 6 Ω resistor and a CCVS that produces a voltage drop of 3·Ix in the clockwise direction. Ix is the downward current in the shared 4 Ω resistor. Both mesh currents I1 and I2 are clockwise, so in the shared branch Ix = I1 − I2.
Mesh 1:
−12 + 2·I1 + 4·(I1 − I2) = 0, which gives 6·I1 − 4·I2 = 12
Mesh 2:
4·(I2 − I1) + 6·I2 + 3·(I1 − I2) = 0, which gives −I1 + 7·I2 = 0
Substituting I1 = 7·I2 into mesh 1 gives 38·I2 = 12. So I2 = 6/19 A ≈ 0.316 A, I1 = 42/19 A ≈ 2.21 A, and Ix = 36/19 A ≈ 1.89 A.
Supermeshes
KVL needs the voltage across every element, and an ideal current source has an unknown voltage. If a current source sits in a branch shared by two meshes, skip the two separate mesh equations. Instead, write one KVL equation around the outer boundary of the combined loop, which is the supermesh. Then add a constraint equation that ties the mesh currents to the source value.
Example 2: a supermesh
Take the same layout, but replace the shared 4 Ω resistor with a 2 A current source pointing downward. The left mesh has the 12 V source and 2 Ω. The right mesh has 6 Ω.
- Constraint: I1 − I2 = 2
- Supermesh KVL: −12 + 2·I1 + 6·I2 = 0
Substitute I1 = I2 + 2. Then −12 + 2·I2 + 4 + 6·I2 = 0, so I2 = 1 A and I1 = 3 A.
Check: 2·3 + 6·1 = 12 V, which matches the source.
If the current source is dependent, for example 0.5·Ix, the constraint still has the same form, with the controlling variable rewritten in mesh currents.
Common errors
- Writing a voltage across a current source as zero or as a guess.
- Forgetting the constraint equation, which leaves the system with too few equations.
- Leaving the controlling variable in its own units (a voltage or branch current) instead of converting it to mesh currents.
- Using the wrong sign for the shared-branch current. It is I1 − I2 or I2 − I1, depending on which mesh you are writing.
Exercise
Repeat Example 2 with a 24 V source instead of 12 V and the same 2 A source. What are I1 and I2?
Show answer
The constraint is I1 = I2 + 2. The supermesh KVL is −24 + 2·I1 + 6·I2 = 0. Substituting gives −24 + 2·I2 + 4 + 6·I2 = 0, so I2 = 2.5 A and I1 = 4.5 A. Check: 2·4.5 + 6·2.5 = 24 V.