Sub topic 3
RL low-pass and high-pass filters
This chapter assumes you know Ohm's law, the voltage divider rule, phasor impedances (ZR = R, ZL = jωL), complex numbers in magnitude and angle form, and logarithms.
RL low-pass and high-pass filters
An RL filter is a resistor and an inductor in series. The output is taken across one of the two parts:
- Output across R gives a low-pass filter: H(jω) = R / (R + jωL).
- Output across L gives a high-pass filter: H(jω) = jωL / (R + jωL).
The two transfer functions add to 1, so the low-pass and high-pass outputs complement each other. At low frequency, the inductor is nearly a short circuit, so the output across R follows the input. At high frequency, the inductor blocks the signal and the output across R falls toward zero.
Time constant and cutoff frequency
The time constant is τ = L/R, in seconds. The cutoff frequency is fc = R / (2πL) = 1 / (2πτ). At fc, the low-pass magnitude is 1/√2 (-3 dB) and the phase is -45°.
Source resistance and load resistance
A source resistance Rs sits in series with the input, so it adds to R in the low-pass divider. The cutoff becomes fc = (R + R_s) / (2πL).
A load R_L connected across the output appears in parallel with the output resistor. This lowers the passband gain and shifts the cutoff.
Checking results with a script and an AC simulation
This script evaluates the RL low-pass filter at one-tenth, one, and ten times the cutoff frequency:
import numpy as np
R = 62.8 # ohms
L = 10e-3 # henries
fc = R / (2 * np.pi * L)
print(f"fc = {fc:.1f} Hz")
f = np.array([fc / 10, fc, fc * 10])
w = 2 * np.pi * f
H = R / (R + 1j * w * L) # RL low-pass, output across R
for fi, h in zip(f, H):
print(f"{fi:8.1f} Hz {20 * np.log10(abs(h)):7.2f} dB {np.degrees(np.angle(h)):7.2f} deg")The same circuit can be checked in SPICE with an AC sweep:
* RL low-pass, output across R
V1 in 0 AC 1
L1 in out 10m
R1 out 0 62.8
.ac dec 20 10 100k
.endThe simulated -3 dB point should fall near 1 kHz.
Cascading first-order stages
Two identical first-order stages, buffered so they do not load each other, give a second-order response with a roll-off of -40 dB per decade. The -3 dB point of the pair is about 0.644 f_c, which is lower than the cutoff of a single stage.
Poles and zeros of first-order filters
Substitute s = jω to get the s-domain transfer functions:
- Low-pass: H(s) = (R/L) / (s + R/L). It has one pole at s = -R/L and no finite zeros.
- High-pass: H(s) = s / (s + R/L). It has a zero at s = 0 and a pole at s = -R/L.
The pole magnitude, R/L, equals the angular cutoff frequency 2πf_c. Because the pole lies in the left half of the s-plane, the filter is stable.
Exercise
Exercise
An RL low-pass filter uses L = 20 mH. What resistance R gives a cutoff frequency of 2 kHz?
Show answer
R = 2π × 2000 × 0.02 ≈ 251 Ω.