Sub topic 14
Poles and Zeros of First-Order Filters
This chapter assumes you can write H(jω) for an RC or RL filter, find its cutoff frequency, and read a Bode plot. It adds one idea: the same filter can be described by where its transfer function goes to zero or infinity in the s-domain. That description explains the Bode asymptotes you already know.
From jω to s
The transfer functions so far use the variable jω, which describes steady sinusoidal signals. Replace jω with the complex variable s and you get H(s). The RC low-pass filter becomes:
H(s) = 1 / (1 + sRC)
Evaluating H(s) along the imaginary axis, where s = jω, gives back the frequency response you already computed.
Poles and zeros
A pole is a value of s that makes the denominator of H(s) zero, so |H| grows without bound. A zero is a value of s that makes the numerator zero, so H(s) = 0.
For the RC low-pass filter:
- The denominator 1 + sRC is zero at s = -1/(RC). This is the single pole.
- The numerator is the constant 1, so there is no zero at a finite s.
The pole sits on the negative real axis at s = -ωc, where ωc = 1/(RC) is the cutoff frequency in radians per second. For the 1.59 kΩ and 100 nF filter, ωc is about 6290 rad/s, which is 1 kHz.
For the RL high-pass filter with output across the inductor:
H(s) = sL / (R + sL)
- The numerator is zero at s = 0, so there is a zero at the origin.
- The denominator is zero at s = -R/L, so there is a pole at s = -ωc.
Why poles and zeros shape the Bode plot
Each pole and zero produces a predictable change in slope.
| Feature | Location | Effect on magnitude slope | Effect on phase |
|---|---|---|---|
| Pole | s = -ωc | Slope drops by 20 dB/decade above ωc | Adds up to -90° |
| Zero at origin | s = 0 | Rises at +20 dB/decade from the start | Adds +90° at all frequencies |
The low-pass filter is flat until its pole, then falls at -20 dB/decade. The high-pass filter rises at +20 dB/decade because of the zero at the origin. Its slope flattens at the pole, since -20 dB/decade cancels +20 dB/decade. Its phase starts at +90° and falls to 0°, passing through +45° at ωc.
Reading the pole location
The pole position is the cutoff frequency in another form. Moving the pole farther from the origin raises the cutoff. Because the pole is real and negative, the circuit is stable and has no resonant peak. Its step response is a simple exponential with time constant τ = 1/ωc, which matches the earlier link between τ and fc.
Computing poles and zeros numerically
NumPy can find roots of the numerator and denominator polynomials. Coefficients are listed from the highest power of s down.
import numpy as np
R = 62.8 # ohms
L = 10e-3 # henries
# RL high-pass: H(s) = L*s / (L*s + R)
num = [L, 0]
den = [L, R]
zeros = np.roots(num)
poles = np.roots(den)
print("zeros:", zeros)
print("poles:", poles)
print(f"pole frequency = {abs(poles[0]) / (2 * np.pi):.1f} Hz")The script reports a zero at 0 and a pole near -6280 rad/s, which is about 1 kHz.
Exercise
An RC high-pass filter has R = 1 kΩ and C = 159 nF. Write H(s), then state where its pole and zero are and the cutoff frequency in Hz.
Show answer
H(s) = sRC / (1 + sRC). The zero is at s = 0. The pole is at s = -1/(RC) = -1/(1000 × 159e-9) ≈ -6290 rad/s. The cutoff frequency is 6290 / (2π) ≈ 1000 Hz, or 1 kHz.