Sub topic 12
Objective Hand Measurement with KES and FAST
This chapter assumes you know the vocabulary from the earlier chapters: gsm, drape, the drape coefficient, and hand terms such as crisp, supple, and stiff. You do not need any statistics background. The goal is to understand what the two main instrument systems measure, how their numbers relate to the words you already use, and where they fall short.
Why measure hand with instruments
Hand is a judgment made by touch. Two experienced buyers can disagree about whether a wool is "soft" or "supple". A mill in one country and a brand in another may use the same word for different things. Instruments solve this by turning handling behavior into numbers that can be compared, stored, and written into a specification.
Instruments do not replace your hands. They give you a shared reference when a fabric cannot be handled, for example when you order online, when a factory must match an approved sample, or when you compare many candidates quickly.
The idea behind both systems
Hand is not one property. When you pinch, bend, and stroke a fabric, you sense several mechanical behaviors at once:
- How much it resists bending (stiffness).
- How easily it stretches, and whether it recovers.
- How much it resists shearing, which is the sideways distortion of the weave or knit.
- How much it compresses under light pressure, and how much it springs back.
- How rough or slippery the surface is.
- How heavy it is for its thickness.
Both systems measure these behaviors with small forces, similar to the forces in hand-handling. Large forces would test strength, which is a different question. Hand lives in the low-force range, so the instruments are built to be sensitive there.
KES: the Kawabata Evaluation System
The Kawabata Evaluation System (KES) was developed in Japan by Sueo Kawabata and colleagues, starting in the 1970s. It uses four benchtop instruments. Each one tests a different kind of deformation.
| Instrument | Property group | What it does | Example parameters |
|---|---|---|---|
| KES-FB1 | Tensile and shear | Stretches the sample lightly, then shears it sideways | EMT (extensibility), LT (linearity), RT (resilience), G (shear stiffness), 2HG (shear hysteresis) |
| KES-FB2 | Pure bending | Bends a strip in a smooth curve and back | B (bending rigidity), 2HB (bending hysteresis) |
| KES-FB3 | Compression | Presses a small plate onto the fabric | LC (linearity), WC (compression energy), RC (resilience) |
| KES-FB4 | Surface | Slides a sensor across the fabric | MIU (friction coefficient), MMD (friction variation), SMD (geometric roughness) |
The system also records thickness (T) and weight per area (W), so the full set is about sixteen mechanical parameters plus those two.
Reading the parameters
Two ideas help you interpret these numbers.
Rigidity versus hysteresis. A rigidity value, such as B for bending or G for shear, tells you how hard it is to deform the fabric. A higher B means a stiffer fabric. Hysteresis, such as 2HB or 2HG, tells you how much of the deformation does not come back when the force is removed. A fabric with high hysteresis stays creased or bent. A fabric with low hysteresis springs back.
Surface values. A higher MIU means more friction and a grabbier surface. A higher MMD means the friction is uneven, which you feel as roughness. A higher SMD means the surface is geometrically bumpy.
These parameters connect directly to what you already know about drape. Low bending rigidity (B) and low shear stiffness (G) together are the mechanical signature of a fabric that drapes softly. High B and high G mean a fabric that holds its own shape.
From parameters to hand values
Kawabata did not stop at raw parameters. His group asked panels of experienced judges to rate fabrics on primary hand attributes, then fitted equations that predict those ratings from the measured parameters. For men's winter suiting, the primary hand attributes were:
- Koshi: stiffness, a springy resistance to bending.
- Numeri: smoothness, a combination of slickness and soft fullness.
- Fukurami: fullness and softness, a bulky, spongy quality.
- Shari: crispness, a firm, cool, rough surface feel.
- Hari: anti-drape stiffness, the tendency to stand away from the body.
These are Japanese terms from the original research. Separate equations exist for other fabric categories, such as men's summer suiting and women's thin dress fabrics. The equations are tied to the category they were fitted on, which matters for the limits discussed below.
The result is a hand value, often on a scale from 0 to 10, and a total hand value (THV) that rates overall quality for that end use. Higher THV means the panel judged the fabric better for that category.
FAST: Fabric Assurance by Simple Testing
FAST was developed in Australia by CSIRO in the late 1980s. The aim was different from KES. KES is a research tool, and the instruments are slow and costly to run. FAST was designed for use in garment factories and finishing mills, to check whether a fabric will tailor, press, and hold its shape properly.
FAST uses three instruments and one simple test.
| Module | Measures | Why it matters |
|---|---|---|
| FAST-1 Compression meter | Thickness at two pressures, and thickness after relaxing | Surface layer thickness, which changes with pressing and finishing |
| FAST-2 Bending meter | Bending length, from which bending rigidity is calculated | Stiffness and drape |
| FAST-3 Extension meter | Extension at three loads in warp, weft, and bias directions | Stretch behavior, and how easily the fabric forms to a shape |
| FAST-4 Dimensional stability test | Relaxation shrinkage and hygral expansion | Whether the fabric changes size when wet or steamed |
FAST is aimed at tailoring decisions. For example, a fabric with high extension at low load in the bias direction is easy to mold around a curve, but may also be prone to seam puckering or distortion. High hygral expansion warns that a garment may grow or ripple after pressing or humidity changes.
Comparing KES and FAST
| Feature | KES | FAST |
|---|---|---|
| Origin | Japan, Kawabata | Australia, CSIRO |
| Number of instruments | Four | Three plus a dimensional test |
| Typical user | Researchers, large mills, labs | Garment makers, finishers |
| Speed and cost | Slow, expensive | Faster, cheaper |
| Output | Many mechanical parameters, plus hand values | Fewer parameters, plus a control chart |
| Main goal | Describe and predict hand | Predict tailoring and finishing performance |
FAST results are often plotted on a control chart. Each parameter has a band showing the typical range for a fabric type. A value outside the band flags a likely problem before cutting begins.
A small calculation: bending rigidity from bending length
You can see the logic of these instruments with a simple calculation. In the cantilever test, a fabric strip is pushed over an edge until it bends under its own weight. The overhang length at a standard angle is the bending length. Bending rigidity is then:
G = W × c³
where W is weight per unit area and c is the bending length. Because c is cubed, a small difference in bending length makes a large difference in rigidity. This script shows it.
def bending_rigidity(weight_gsm, bending_length_cm):
"""Flexural rigidity per unit width in micro-newton meters.
weight_gsm: fabric mass per area in g/m^2
bending_length_cm: overhang length in cm at the 41.5 degree angle
"""
g = 9.81 # m/s^2
weight_per_area = weight_gsm / 1000 * g # N/m^2
c = bending_length_cm / 100 # meters
rigidity = weight_per_area * c ** 3 # N*m
return rigidity * 1e6 # micro-newton meters
soft = bending_rigidity(120, 2.5)
stiff = bending_rigidity(120, 4.0)
print(round(soft, 1)) # 18.4
print(round(stiff, 1)) # 75.3
print(round(stiff / soft, 1)) # 4.1Both fabrics weigh 120 gsm. The stiff one has a bending length only 1.6 times longer, but it is about four times more rigid. This also supports the point from the first chapter: weight alone does not predict how a fabric behaves.
Limits and common errors
Instrument numbers are useful, but they are easy to misuse.
- Comparing across categories. The Kawabata hand equations were fitted on specific fabric types. Applying the men's winter suiting equation to a silk charmeuse gives a number, but the number has no meaning.
- Treating THV as quality. THV reflects the preferences of the original Japanese judging panels for a given end use. A different market may prefer a different hand.
- Ignoring the test conditions. Humidity, relaxation state, and sample preparation change results. Wool and cotton are especially sensitive to moisture. Compare only samples tested under the same conditions.
- Testing only one direction. Fabrics behave differently along warp, weft, and bias, as covered in the grain chapter. Check that the report gives values for each direction.
- Expecting the numbers to replace a swatch. A report does not tell you whether a fabric looks right, or how it feels against your skin.
- Reading one parameter alone. Hand comes from the combination. A low B with a high 2HB describes a limp fabric that creases, which is very different from a low B with a low 2HB.
Connecting numbers back to your vocabulary
The table below maps the hand words you already know to the measurements that tend to explain them. It is a guide, not a formula.
| Hand word | Typical mechanical signature |
|---|---|
| Crisp | High bending rigidity, low hysteresis, rough or dry surface |
| Soft | Low bending rigidity, high compressibility |
| Supple | Low bending rigidity, low shear stiffness, low hysteresis |
| Stiff | High bending rigidity and high shear stiffness |
| Limp | Low rigidity, high hysteresis |
| Slick | Low MIU and low MMD |
Exercise
Two cotton shirting fabrics both weigh 110 gsm. Fabric X has a bending rigidity (B) twice that of Fabric Y, and a much lower shear hysteresis (2HG). Which fabric will hold its shape better, which will stay creased longer, and why can you not decide this from the 110 gsm figure?
Show answer
Fabric X holds its shape better because higher bending rigidity means more resistance to bending. Fabric Y is likelier to stay creased or deformed, because higher shear hysteresis means it recovers less after being distorted. Fabric X recovers better thanks to its low 2HG. The 110 gsm figure says nothing about stiffness or recovery. Both depend on fiber, yarn, construction, and finish, which is why equal-weight fabrics can behave very differently.
Exercise
A garment factory wants to know whether a wool-blend fabric will ripple after pressing. Would you choose KES or FAST for this check, and which measurement is most relevant?
Show answer
FAST is the better choice, because it was designed for factory use and includes a dimensional stability test. The relevant measurement is hygral expansion (with relaxation shrinkage), which shows how much the fabric changes size with moisture and steam.