Sub topic 1
Measurement, units and what an experiment reports
Every experiment reports a number with a unit and an uncertainty. This chapter covers how instruments produce those numbers and how to write them correctly.
Prerequisites
This chapter assumes you know the SI base units (metre, kilogram, second, ampere), can do basic algebra, and have seen a metre scale before.
Measurement and units
A measurement compares a physical quantity with a standard unit. A length of 24.4 mm means the object is 24.4 times the size of one millimetre. Always write the unit with the number. A value without a unit has no physical meaning.
Least count: the resolution of an instrument
The least count is the smallest value an instrument can measure reliably. A metre scale marked in millimetres has a least count of 1 mm. Readings finer than the least count are estimates, not measurements.
Reading a vernier caliper
A vernier caliper has a main scale and a sliding vernier scale. Its least count is:
LC = (1 main scale division) minus (1 vernier division)
For a common caliper, 10 vernier divisions match 9 main scale divisions of 1 mm. So LC = 1 mm minus 0.9 mm = 0.1 mm.
The reading is:
Reading = main scale reading + (coinciding vernier division × LC) − zero error
Reading a screw gauge
A screw gauge has a pitch of 0.5 mm and a circular scale with 50 divisions. Its least count is 0.5 mm / 50 = 0.01 mm.
Reading = pitch scale reading + (circular scale division × LC) − zero error
Zero error and zero correction
Zero error is the reading an instrument gives when its jaws are fully closed. Its true value is zero, so any other reading is an error. A positive zero error is subtracted from every reading, and a negative zero error is added. This subtraction is the zero correction.
The following code applies the vernier formula with a zero correction:
def corrected_reading(msr, coincide, least_count, zero_error):
"""Vernier reading minus zero error. All lengths in mm."""
raw = msr + coincide * least_count
return round(raw - zero_error, 2)
print(corrected_reading(24, 6, 0.1, 0.2)) # prints 24.4> The raw reading is 24.6 mm. The zero error of +0.2 mm is subtracted to give 24.4 mm.
Significant figures and rounding a result
Significant figures are the digits that carry real information. Non-zero digits always count. Zeros between non-zero digits count. Leading zeros do not count. For example, 0.0320 has three significant figures.
Round your final result to match the precision of the instrument. A result from a 0.01 mm screw gauge should carry two decimal places in millimetres, such as 3.44 mm, not 3.4417 mm.
Exercise
Exercise
A vernier caliper has a least count of 0.1 mm and a zero error of 0.0 mm. The main scale reading is 12 mm and the coinciding vernier division is 7. What is the corrected reading?
Show answer
Raw reading = 12 + 7 × 0.1 = 12.7 mm. The zero error is 0, so the corrected reading is 12.7 mm.