Sub topic 20
From 10 Mbps Ethernet to Gigabit Ethernet
This chapter assumes you know the CSMA/CD rules, the slot time and minimum frame size derivation, the CSMA/CD efficiency formula, and how learning switches split collision domains. Here you will see what changed as Ethernet got faster and what stayed fixed. GATE questions often test this as "what happens to the minimum frame size or the maximum cable length when the speed rises".
What stayed the same
Every Ethernet generation from 10 Mbps to 10 Gbps keeps the same frame format: preamble, destination and source MAC addresses, type or length, payload of 46 to 1500 bytes, and a 4-byte CRC-32 frame check sequence. The minimum frame is 64 bytes and the maximum is 1518 bytes. Because the frame does not change, a bridge or switch can connect a 10 Mbps port to a 100 Mbps port without rebuilding frames.
The classic 10 Mbps generation
The original standards differ in cable and topology, not in the MAC protocol.
- 10BASE5 (thick coax) is a bus with segments up to 500 m.
- 10BASE2 (thin coax) is a bus with segments up to 185 m.
- 10BASE-T (twisted pair) wires each station to a central hub in a star, with links up to 100 m. A hub repeats every bit to all ports, so the whole hub is still one collision domain.
All three use CSMA/CD at 10 Mbps with a 512-bit slot time of 51.2 µs.
Fast Ethernet: 100 Mbps
Fast Ethernet (100BASE-TX over Category 5 twisted pair, 100 m per link) kept the frame format and the 64-byte minimum. The bit rate rose tenfold, so the time to send 512 bits fell tenfold, to 5.12 µs. The collision must still reach the sender before it finishes the frame. The round-trip propagation time therefore had to shrink by the same factor, which cut the allowed network diameter from several kilometres to roughly 200 m.
The designers accepted the shorter diameter because the star topology with 100 m links already fit inside it.
The general rule
For a half-duplex network the slot time must cover the worst-case round trip. If the minimum frame is L bits and the bandwidth is B, then:
L / B ≥ 2 × (propagation delay across the network)
The maximum one-way span is therefore (L / B) × v / 2, where v is the signal speed, about 2 × 10^8 m/s in cable. Raising B with L fixed shrinks the span in proportion.
SPEED = 2e8 # signal speed in m/s, about two thirds of c
def max_span_m(bandwidth_bps, min_frame_bits):
slot_time = min_frame_bits / bandwidth_bps
return slot_time * SPEED / 2 # one-way distance
cases = [
("10 Mbps, 64 B", 10e6, 512),
("100 Mbps, 64 B", 100e6, 512),
("1 Gbps, 64 B", 1e9, 512),
("1 Gbps, 512 B (carrier extension)", 1e9, 4096),
]
for name, bw, bits in cases:
print(f"{name}: {max_span_m(bw, bits):.1f} m")The output is 5120.0 m, 512.0 m, 51.2 m and 409.6 m. These are idealized values. Real standards give smaller limits because repeaters, the interframe gap and signal-detection time use up part of the slot.
Gigabit Ethernet: 1000 Mbps
Keeping a 64-byte slot at 1 Gbps would limit the span to about 51 m, which is too short to be useful. The designers considered raising the minimum frame size, but that would break compatibility with the older frame format. They chose a different fix for half-duplex mode: carrier extension.
- The slot time becomes 4096 bit times (4.096 µs), equal to 512 bytes.
- If a frame is shorter than 512 bytes, the sender appends special extension symbols after the FCS until the transmission lasts 512 bytes.
- The receiver discards the extension. It is not part of the frame, and the FCS does not cover it.
- The frame itself is still 64 to 1518 bytes.
Carrier extension wastes bandwidth on small frames. A 64-byte frame occupies 512 bytes of channel time, so at most one eighth of the time carries real frame bytes. Frame bursting reduces this cost. After the first frame (extended if needed) is sent, the station may send further frames back to back, with only the interframe gap between them, until a burst limit of 8192 bytes is reached. Only the first frame needs extension, because the channel stays busy and other stations stay silent.
Efficiency gets worse as speed rises
Recall the CSMA/CD efficiency formula, 1 / (1 + 6.44a), where a = Tp / Tt is the propagation time divided by the frame transmission time. Take a 12000-bit frame and a network with Tp = 25.6 µs.
| Bandwidth | Tt | a | Efficiency |
|---|---|---|---|
| 10 Mbps | 1200 µs | 0.0213 | about 0.88 |
| 1 Gbps | 12 µs | 2.13 | about 0.068 |
The cable length did not change, but the frame became 100 times shorter in time. That is the reason half-duplex gigabit is almost never used.
Full-duplex switched Ethernet
When a switch port connects to exactly one station over a link with separate transmit and receive paths (twisted pair or fiber), no two stations can collide. The standards then turn CSMA/CD off. Three consequences follow:
- The slot-time rule no longer limits the cable length. Length is limited only by signal quality: 100 m for twisted pair, and from hundreds of meters to many kilometers for fiber, depending on the type.
- The 64-byte minimum remains, but only for compatibility and for receivers that sort out damaged frames. It no longer comes from collision detection.
- The link can reach its full rate in both directions at once.
10 Gigabit Ethernet and faster are defined only for full-duplex operation, so they have no CSMA/CD at all.
Summary of the generations
| Standard | Rate | Typical medium | Min frame on the wire | Slot time | MAC mode |
|---|---|---|---|---|---|
| 10BASE5 / 10BASE2 | 10 Mbps | Coax bus | 64 B | 51.2 µs | CSMA/CD |
| 10BASE-T | 10 Mbps | Twisted pair, hub | 64 B | 51.2 µs | CSMA/CD |
| 100BASE-TX | 100 Mbps | Cat 5 twisted pair | 64 B | 5.12 µs | CSMA/CD or full-duplex |
| 1000BASE-T | 1 Gbps | Cat 5e, four pairs | 512 B with extension | 4.096 µs | Full-duplex in practice |
| 10GBASE-* | 10 Gbps | Fiber or twisted pair | 64 B | not used | Full-duplex only |
Common mistakes
- Saying Gigabit Ethernet has a 512-byte minimum frame. The minimum frame is still 64 bytes. Only the transmission time is extended, and only in half-duplex mode.
- Computing the new minimum frame size from the old slot time. If an exam says the network diameter and speed are fixed, use L = B × 2Tp, and do not carry over 64 bytes.
- Forgetting that the extension is excluded from the FCS and from the frame length.
Exercise
A half-duplex CSMA/CD network runs at 100 Mbps. The maximum round-trip propagation time is 5.12 µs and the minimum frame size is 64 bytes. The speed is raised to 1 Gbps on the same cable, and the frame format must not change. (a) What transmission time must a sender fill, and how many bytes is that at 1 Gbps? (b) What is the minimum frame size if the standard instead required the frame itself to be long enough? (c) What mechanism does Gigabit Ethernet use, and what does it do for frames shorter than this?
Show answer
(a) The sender must transmit for at least the round-trip time of 5.12 µs. At 1 Gbps this is 1e9 × 5.12e-6 = 5120 bits = 640 bytes. (b) If the frame itself had to be that long, the minimum frame would be 640 bytes. The standard avoids this because it would break the 64-byte format. (c) Gigabit Ethernet uses carrier extension. It pads the transmission with extension symbols after the FCS to reach the slot time, without changing the frame. The real standard uses a smaller diameter, so its slot time is 512 bytes.
Exercise
A 1 Gbps half-duplex link has a minimum slot of 512 bytes and a signal speed of 2 × 10^8 m/s. Ignoring repeater delay, what is the maximum one-way cable length? What is the efficiency of a 12000-bit frame if Tp is half the slot time, using 1 / (1 + 6.44a)?
Show answer
Slot time = 4096 / 1e9 = 4.096 µs, so one-way length = 4.096e-6 × 2e8 / 2 = 409.6 m. Tp = 2.048 µs and Tt = 12000 / 1e9 = 12 µs, so a = 0.1707. Efficiency = 1 / (1 + 6.44 × 0.1707) = 1 / 2.099 ≈ 0.476.