Sub topic 13
Rectifiers: Half-Wave and Full-Wave
This chapter assumes you know how a p-n junction diode behaves under forward and reverse bias, the idea of a barrier potential, and basic AC terms such as peak value, RMS value and frequency. You should also know Ohm's law for a resistor.
Why Rectification Is Needed
Mains supply is alternating current (AC). Most electronic circuits need direct current (DC), which flows in one direction only. A rectifier is a circuit that converts AC into a current that flows in one direction through the load. The diode makes this possible because it conducts when forward biased and blocks when reverse biased.
In the ideal-diode model used for most JEE problems, a forward-biased diode has zero resistance and a reverse-biased diode has infinite resistance. When a problem gives a forward drop (about 0.7 V for silicon), subtract it from the input voltage while the diode conducts.
Half-Wave Rectifier
Circuit and Working
A half-wave rectifier uses one diode in series with the load resistor R_L. The input is the secondary of a transformer, which sets the AC voltage to the level you need.
- During the positive half-cycle, the diode is forward biased. It conducts, and the load receives the positive half of the wave.
- During the negative half-cycle, the diode is reverse biased. It blocks, and the load current is zero.
The output is a train of positive pulses, one for each input cycle. Half of the input wave is wasted.
Output Frequency
Because there is one pulse per input cycle, the output frequency equals the input frequency. For 50 Hz mains, the output ripple frequency is 50 Hz.
Average and RMS Values
Let the peak voltage across the load be V0 (ignoring the diode drop). The output is V0 sin(ωt) for half the period and zero for the other half.
- Average (DC) value: Vdc = V0/π ≈ 0.318 V_0
- RMS value: Vrms = V0/2 = 0.5 V_0
The same ratios apply to current: Idc = I0/π and Irms = I0/2.
Efficiency and Ripple
Rectification efficiency is the ratio of DC power delivered to the load to the AC power supplied to the circuit.
η = Pdc / Pac = (Idc² RL) / (Irms² (RL + r_f))
For an ideal diode with forward resistance r_f = 0, this gives:
η = (I0/π)² / (I0/2)² = 4/π² ≈ 0.405, or 40.5%
The ripple factor measures how much AC remains in the output:
γ = sqrt((Vrms/Vdc)² − 1)
For a half-wave rectifier, Vrms/Vdc = π/2, so γ = sqrt(π²/4 − 1) ≈ 1.21. A ripple factor above 1 means the output has more AC content than DC content, so it is a poor DC source.
Full-Wave Rectifier
A full-wave rectifier uses both half-cycles of the input. There are two common designs.
Centre-Tapped Design
This design uses a transformer whose secondary has a centre tap, and two diodes D1 and D2.
- During the first half-cycle, the top end of the secondary is positive. D1 conducts and D2 is reverse biased.
- During the second half-cycle, the bottom end is positive. D2 conducts and D1 is reverse biased.
In both half-cycles the current passes through the load in the same direction. Each diode sees only half of the secondary voltage, so each half of the secondary must supply the peak value V0. The reverse voltage across the non-conducting diode is about 2V0, so the diodes need a peak inverse voltage (PIV) rating of at least 2V_0.
Bridge Design
The bridge rectifier uses four diodes and a plain secondary with no centre tap.
- In one half-cycle, one pair of diodes conducts.
- In the other half-cycle, the other pair conducts.
- The current through the load has the same direction in both cases.
Two diodes are in the current path at any instant, so the output loses two forward drops, which is about 1.4 V for silicon. Each diode's PIV only needs to be V_0.
Output Frequency
The output has two pulses per input cycle, so the output frequency is twice the input frequency. For 50 Hz mains, the ripple frequency is 100 Hz.
Average and RMS Values
The output is |V_0 sin(ωt)|, so:
- Vdc = 2V0/π ≈ 0.637 V_0
- Vrms = V0/√2 ≈ 0.707 V_0
Efficiency and Ripple
For an ideal diode, η = (2I0/π)² / (I0/√2)² = 8/π² ≈ 0.811, or 81.1%.
The ripple factor is γ = sqrt((π/(2√2))² − 1) ≈ 0.48. This is lower than for the half-wave circuit.
Comparison
| Quantity | Half-wave | Full-wave |
|---|---|---|
| Diodes used | 1 | 2 (centre-tap) or 4 (bridge) |
| Output frequency (input f) | f | 2f |
| V_dc | V_0/π | 2V_0/π |
| V_rms | V_0/2 | V_0/√2 |
| Maximum efficiency | 40.5% | 81.1% |
| Ripple factor | 1.21 | 0.48 |
Filtering
The output of either rectifier is pulsating DC. A capacitor placed in parallel with the load charges while the diode conducts near the peak and discharges slowly through RL while the diode is off. This fills in the gaps and smooths the output. A larger capacitor or a larger RL gives a longer discharge time constant R_L C and a smoother output. Full-wave output is easier to filter because its pulses are twice as frequent, so the capacitor has less time to discharge between peaks.
Common Errors
- Stating that the half-wave output frequency is 2f, or the full-wave output frequency is f. It is the other way round.
- Using V0 as the RMS value. The RMS value of the full-wave output is V0/√2, and for half-wave it is V_0/2.
- Forgetting that a given RMS input (for example, 220 V) means a peak of 220√2 V ≈ 311 V.
- Forgetting the diode drop in a bridge, where two diodes conduct together.
- Confusing the DC meter reading (the average value) with the RMS value. A moving-coil DC meter reads the average.
Worked Example
A full-wave rectifier is fed by a 50 Hz source with peak voltage 20 V. Ideal diodes are used and R_L = 100 Ω. Find the DC load current and the ripple frequency.
The peak current is I0 = 20/100 = 0.20 A. The DC current is Idc = 2I_0/π = 0.40/π ≈ 0.127 A. The ripple frequency is 2 × 50 = 100 Hz.
The code below computes these values for both rectifier types.
import math
def rectifier_values(v0, r_load, f_in, full_wave):
i0 = v0 / r_load
if full_wave:
i_dc = 2 * i0 / math.pi
i_rms = i0 / math.sqrt(2)
f_out = 2 * f_in
else:
i_dc = i0 / math.pi
i_rms = i0 / 2
f_out = f_in
efficiency = (i_dc ** 2) / (i_rms ** 2)
ripple = math.sqrt((i_rms / i_dc) ** 2 - 1)
return i_dc, i_rms, f_out, efficiency, ripple
for name, full in (("half-wave", False), ("full-wave", True)):
i_dc, i_rms, f_out, eta, gamma = rectifier_values(20.0, 100.0, 50.0, full)
print(f"{name}: I_dc = {i_dc:.3f} A, I_rms = {i_rms:.3f} A, "
f"f_out = {f_out:.0f} Hz, efficiency = {eta*100:.1f}%, ripple = {gamma:.2f}")Exercise
A half-wave rectifier is connected to a 220 V (RMS), 50 Hz supply through an ideal diode and a 1 kΩ load. Find the DC load current (use √2 ≈ 1.41 and π ≈ 3.14) and the output ripple frequency.
Show answer
The peak voltage is 220 × 1.41 ≈ 310 V, so I0 = 310/1000 = 0.31 A. The DC current is I0/π = 0.31/3.14 ≈ 0.099 A, or about 99 mA. The ripple frequency equals the input frequency, which is 50 Hz.
Exercise
A bridge rectifier uses silicon diodes (0.7 V drop each) and a transformer secondary of peak voltage 12 V. What is the peak voltage across the load, and what is the ripple frequency for a 50 Hz input?
Show answer
Two diodes conduct at any instant, so the total drop is 2 × 0.7 = 1.4 V. The peak load voltage is 12 − 1.4 = 10.6 V. The ripple frequency is 2 × 50 = 100 Hz.
Exercise
Why does a full-wave rectifier have a higher efficiency than a half-wave rectifier, and what are the two efficiency values for ideal diodes?
Show answer
A full-wave rectifier uses both half-cycles, so the DC output power relative to the AC input power is doubled. The ideal efficiencies are 40.5% (4/π²) for half-wave and 81.1% (8/π²) for full-wave.