Sub topic 18
The ideal transformer and its losses
This chapter assumes you know Faraday's law, mutual inductance, RMS values and the idea of average power and power factor in an AC circuit.
What a transformer does
A transformer changes the amplitude of an alternating voltage without changing its frequency. It has two coils wound on a common soft-iron core. The primary coil (Np turns) is connected to the AC source. The secondary coil (Ns turns) is connected to the load.
The alternating primary current produces an alternating flux in the core. The core guides almost all of this flux through the secondary, so the same changing flux links both coils. It works only with AC, because a steady flux induces no EMF.
Ideal transformer relations
An ideal transformer has no resistance in its windings, no flux leakage, no core losses, and a core of very high permeability. Each turn sees the same flux change dΦ/dt, so the EMF per turn is the same in both coils:
- Voltage: Vs / Vp = Ns / Np
- Power: Vp Ip = Vs Is, so Is / Ip = Np / Ns
- Step-up: Ns > Np, giving a higher voltage and a lower current.
- Step-down: Ns < Np, giving a lower voltage and a higher current.
Voltage and current change in opposite directions. A transformer cannot raise power.
Worked example
A step-down transformer has 2000 primary turns and 100 secondary turns. It is connected to a 220 V supply and delivers current to a 5 Ω load.
Np, Ns = 2000, 100
Vp = 220.0
R_load = 5.0
Vs = Vp * Ns / Np # 11 V
Is = Vs / R_load # 2.2 A
Ip = Is * Ns / Np # 0.11 A (ideal: power in = power out)
print(Vs, Is, Ip)
print(Vp * Ip, Vs * Is) # both 24.2 WThe secondary voltage is 11 V. The secondary current is 2.2 A and the primary current is 0.11 A. Both sides carry 24.2 W.
Real losses
A real transformer has efficiency η = Pout / Pin, which is below 1. The main losses are:
| Loss | Cause | Reduced by |
|---|---|---|
| Copper loss | I²R heating in the windings | Thicker wire |
| Eddy-current loss | Induced currents circulating in the core | Laminated core, with insulated thin sheets |
| Hysteresis loss | Energy spent in repeatedly reversing the core's magnetisation | Soft iron with a narrow hysteresis loop |
| Flux leakage | Some flux does not link both coils | Winding the coils on top of each other, on a closed core |
| Humming (magnetostriction) | Vibration of the core | Tight clamping |
Why transmission uses high voltage
For delivering power P through lines of resistance R, the line current is I = P/V. The line loss is I²R = P²R/V². Stepping the voltage up by a factor of 10 cuts the line loss by a factor of 100. This is why power stations step the voltage up for transmission and substations step it down for use.
Exercise
A transformer with 50 primary turns and 500 secondary turns is connected to a 12 V AC source. Its efficiency is 90% and the secondary current is 0.5 A. Find the secondary voltage, the input power and the primary current.
Show answer
Vs = 12 × 500/50 = 120 V. Pout = 120 × 0.5 = 60 W. Pin = Pout/η = 60/0.9 ≈ 66.7 W. Primary current Ip = Pin/V_p = 66.7/12 ≈ 5.56 A (taking the primary power factor as 1).
Exercise
Why is the core of a transformer made of thin, insulated laminated sheets rather than a solid block of iron?
Show answer
A solid block lets large eddy currents circulate in it, causing I²R heating. Thin insulated sheets break these current loops and raise the resistance of each path, so the eddy-current loss falls sharply.