Sub topic 11
Mutual Inductance
This chapter assumes you know Faraday's law, Lenz's law, magnetic flux through a surface, and the self-inductance idea from the previous chapter. You should also be comfortable with basic derivatives and with the field of a long solenoid, B = μ₀nI.
The idea
Faraday's law says that a changing flux through a circuit induces an emf in it. Nothing in the law requires the changing flux to come from that circuit's own current. If two circuits sit near each other, the magnetic field made by circuit 1 passes through circuit 2. When the current in circuit 1 changes, the flux through circuit 2 changes, and an emf appears in circuit 2.
This coupling between separate circuits is called mutual inductance. Self-inductance describes how a circuit responds to its own changing current. Mutual inductance describes how one circuit responds to a changing current in another.
Definition
Take two coils. Coil 1 carries current I₁. Coil 2 has N₂ turns. Let Φ₂₁ be the flux that the field of coil 1 produces through one turn of coil 2. The field is proportional to I₁, so the total flux linkage through coil 2 is proportional to I₁. The constant of proportionality is the mutual inductance M₂₁:
N₂ Φ₂₁ = M₂₁ I₁
Faraday's law applied to coil 2 gives:
ε₂ = −N₂ dΦ₂₁/dt = −M₂₁ dI₁/dt
The unit of M is the henry (H), the same as for self-inductance: 1 H = 1 V·s/A.
The symmetry result
You can define M₁₂ the other way around, using the current in coil 2 and the flux it sends through coil 1. A result called the reciprocity theorem (it follows from the Neumann formula for two circuits) says:
M₁₂ = M₂₁ = M
Mutual inductance depends only on geometry and on the material between the coils. It does not depend on which coil is the "driver". This is useful in practice. If one direction is hard to compute, calculate the other.
M also depends on the medium. Putting a ferromagnetic core through both coils raises M by a large factor, which is why transformers use iron cores.
Worked example: coaxial solenoids
A long solenoid (coil 1) has n₁ turns per metre, length ℓ and cross-sectional area A. A short coil of N₂ turns is wound tightly around its middle, so every turn of coil 2 encloses the full area A of the solenoid.
- The field inside the solenoid is B = μ₀n₁I₁.
- The flux through one turn of coil 2 is Φ₂₁ = μ₀n₁I₁A.
- The flux linkage is N₂Φ₂₁ = μ₀n₁N₂A I₁.
- So M = μ₀n₁N₂A.
For n₁ = 1000 turns/m, N₂ = 100 and A = 4.0 × 10⁻⁴ m²:
M = (4π × 10⁻⁷)(1000)(100)(4.0 × 10⁻⁴) ≈ 5.0 × 10⁻⁵ H = 50 μH
If I₁ ramps at 20 A/s, the induced emf in coil 2 has magnitude M·dI₁/dt = (5.0 × 10⁻⁵)(20) ≈ 1.0 × 10⁻³ V, or 1 mV.
Notice the reciprocity at work. To compute M from the other side you would need the field of the short coil at every turn of the long solenoid, which is much harder. Choosing the easy direction is the standard trick.
import numpy as np
mu0 = 4 * np.pi * 1e-7
n1 = 1000.0 # turns per metre, solenoid
N2 = 100 # turns, outer coil
A = 4.0e-4 # cross-sectional area, m^2
dI_dt = 20.0 # current ramp in coil 1, A/s
M = mu0 * n1 * N2 * A
emf2 = M * dI_dt
print(f"M = {M * 1e6:.1f} microhenry")
print(f"emf in coil 2 = {emf2 * 1e3:.2f} mV")Direction and Lenz's law
The minus sign in ε₂ = −M dI₁/dt is Lenz's law. If I₁ is increasing, the flux through coil 2 grows, and the current induced in coil 2 produces a field that opposes that growth. If I₁ is decreasing, the induced current in coil 2 tries to keep the flux up.
If I₁ is constant, there is no induced emf at all. Mutual inductance couples only changing currents, so a steady (DC) current in coil 1 passes no signal to coil 2.
The coupling coefficient
Not all of the flux from coil 1 reaches coil 2. Some leaks out into the surrounding space. The coupling coefficient k measures how much is shared:
M = k √(L₁L₂), with 0 ≤ k ≤ 1
Here L₁ and L₂ are the self-inductances of the two coils.
| k | Meaning | Example |
|---|---|---|
| 0 | No shared flux | Coils far apart or at right angles |
| 0.1 to 0.5 | Loose coupling | Wireless charging pad at a distance |
| 0.95 to 0.999 | Tight coupling | Power transformer with an iron core |
| 1 | Ideal, all flux shared | Theoretical limit |
The upper bound k ≤ 1 follows from energy considerations: the magnetic energy of two coupled circuits cannot be negative. (This comes up again in the chapter on energy stored in an inductor.)
For the coaxial solenoid case, check the idea. If the second coil has the same length as the solenoid and the same area, then L₁ = μ₀n₁²Aℓ, L₂ = μ₀n₂²Aℓ, and M = μ₀n₁n₂Aℓ, so M = √(L₁L₂) and k = 1. A real finite solenoid has end effects, so k is slightly lower.
Self-induced and mutual emf together
In a real pair of coupled circuits, each coil has both its own self-inductance and a mutual link to the other. The emf in coil 2 is the sum of two terms:
ε₂ = −L₂ dI₂/dt − M dI₁/dt
and likewise for coil 1:
ε₁ = −L₁ dI₁/dt − M dI₂/dt
The sign of the M term depends on how the coils are wound and on the sign convention for each current. If you connect two coils in series, the total inductance is:
L_total = L₁ + L₂ ± 2M
The plus sign applies when the coils' fields add (series aiding). The minus sign applies when they oppose (series opposing). Measuring both configurations lets you find M experimentally: M = (Laiding − Lopposing)/4.
L_aiding = 0.130 # henry, measured with fields adding
L_opposing = 0.070 # henry, measured with fields opposing
M = (L_aiding - L_opposing) / 4
print(f"M = {M * 1e3:.1f} mH")This gives M = 15.0 mH.
Edge cases and common errors
- Orientation matters. If the axes of the two coils are perpendicular, the flux of one through the other is nearly zero and M is close to 0. Rotating one coil changes M, and M can even change sign when the coil is flipped.
- Distance matters. For two small loops far apart, M falls off roughly as 1/r³, the same dependence as a dipole field.
- Only changing current counts. A constant I₁ gives ε₂ = 0, however large M is.
- Do not confuse M with flux. M is flux linkage per unit current, with units of henry. Flux has units of weber.
- Number of turns. M uses the flux linkage of the coil being measured, so N₂ appears explicitly. Forgetting the factor of N₂ gives an answer too small by that factor.
- Ferromagnetic cores are nonlinear. The definition M = N₂Φ₂₁/I₁ assumes flux is proportional to current. With a saturating iron core this fails at high currents, and M becomes a function of the current.
- Eddy currents. In a solid conducting core, eddy currents reduce the effective coupling at higher frequencies. Laminated cores are used to limit this.
Applications
- Transformers use tight mutual coupling to change voltage levels. The next chapter develops this.
- Wireless charging uses two loosely coupled coils. Efficiency depends strongly on k, so alignment and spacing matter.
- Inductive sensors such as metal detectors and position sensors use changes in M when a conductor or magnet moves nearby.
- Unwanted coupling (crosstalk) occurs when a changing current in one wire induces noise in a neighbouring wire. Twisting pairs of wires and shielding reduce M.
Exercise
Two coils have self-inductances L₁ = 0.20 H and L₂ = 0.80 H, and a coupling coefficient k = 0.50. (a) Find the mutual inductance M. (b) The current in coil 1 changes at 30 A/s. What is the magnitude of the emf induced in coil 2?
Show answer
(a) M = k√(L₁L₂) = 0.50 × √(0.20 × 0.80) = 0.50 × 0.40 = 0.20 H. (b) |ε₂| = M |dI₁/dt| = 0.20 × 30 = 6.0 V.
Exercise
A long solenoid has 500 turns per metre and cross-sectional area 2.0 × 10⁻³ m². A coil of 40 turns is wound around its middle and encloses the whole cross-section. Find M, and state whether M changes if you instead drive current through the 40-turn coil and measure the emf in the solenoid.
Show answer
M = μ₀n₁N₂A = (4π × 10⁻⁷)(500)(40)(2.0 × 10⁻³) ≈ 5.0 × 10⁻⁵ H, about 50 μH. M does not change. By reciprocity, M₁₂ = M₂₁, so the value is the same whichever coil carries the driving current.