Sub topic 10
The parallel-plate capacitor
This chapter derives the capacitance of two parallel plates, explains the assumptions behind the formula, and shows how each variable changes the result. It assumes you know Gauss's law for a sheet of charge, the relation between field and potential difference, and the definition C = Q/V from the previous chapter.
Setup and assumptions
A parallel-plate capacitor has two flat conducting plates, each of area A, separated by a distance d with vacuum (or air) between them. One plate carries +Q and the other carries −Q.
The standard derivation makes two assumptions:
- The plate dimensions are much larger than d, so the field between the plates is uniform and edge effects (fringing) can be ignored.
- The charge sits on the inner faces of the plates, facing each other, because opposite charges attract.
Field between the plates
Treat each plate as a large sheet. An isolated sheet with surface charge density σ = Q/A produces a field of magnitude σ/(2ε0) on each side, directed away from the sheet if it is positive.
Between the plates, the fields of the two sheets point the same way. The positive sheet's field points away from it, toward the negative plate. The negative sheet's field points toward it, which is also toward the negative plate. They add:
E = σ/(2ε0) + σ/(2ε0) = σ/ε0 = Q/(ε0A)
Outside the plates, the two fields point in opposite directions and cancel. The field is therefore confined to the gap.
You can also get E = σ/ε0 from Gauss's law applied to a single conductor surface. The field just outside a conductor is σ/ε0, and the field inside the conductor is zero. The two methods agree.
Deriving C = ε0A/d
Because E is uniform, the potential difference between the plates is the field times the gap:
V = E·d = Qd/(ε0A)
Capacitance is C = Q/V, so:
C = ε0A/d
Charge Q cancels out. The capacitance depends only on geometry (A and d) and on the medium between the plates (here vacuum, with permittivity ε0 = 8.85 × 10⁻¹² F m⁻¹).
| Change | Effect on C |
|---|---|
| Double the plate area A | C doubles |
| Double the separation d | C halves |
| Insert a dielectric (see the dielectrics chapter) | C is multiplied by K |
| Change Q or V | No change |
The last row matters. C is a property of the device. Doubling the charge doubles the voltage, and the ratio Q/V stays fixed.
Worked example 1: numbers for a typical capacitor
Take plates of area A = 0.02 m² separated by d = 1 mm in air.
C = ε0A/d = (8.85 × 10⁻¹² × 0.02) / (1 × 10⁻³) = 1.77 × 10⁻¹⁰ F = 177 pF
This is a small value. A farad is a huge unit, which is why practical capacitors are rated in µF, nF, or pF. To reach even 1 F with a 1 mm gap in air, you would need A = Cd/ε0 ≈ 1.1 × 10⁸ m², about 100 km².
The following program computes capacitance, charge, field and energy for a given geometry and voltage.
EPS0 = 8.85e-12 # F/m
def parallel_plate(area, gap, voltage, k=1.0):
"""Return capacitance, charge, field and stored energy."""
c = k * EPS0 * area / gap
q = c * voltage
e_field = voltage / gap
energy = 0.5 * c * voltage ** 2
return c, q, e_field, energy
c, q, e_field, u = parallel_plate(area=0.02, gap=1e-3, voltage=100.0)
print(f"C = {c:.3e} F") # 1.770e-10 F
print(f"Q = {q:.3e} C") # 1.770e-08 C
print(f"E = {e_field:.3e} V/m") # 1.000e+05 V/m
print(f"U = {u:.3e} J") # 8.850e-07 JThe field of 10⁵ V/m is well below the breakdown field of air, roughly 3 × 10⁶ V/m. If the field exceeds that, air ionises and the capacitor discharges through a spark. For a 1 mm gap, that limit corresponds to about 3000 V.
Force between the plates
The plates carry opposite charges, so they attract. To find the force, note that each plate sits in the field of the other plate only. That field is σ/(2ε0), which is half the total field in the gap.
F = Q × σ/(2ε0) = Q²/(2ε0A)
Using Q = CV, this can be written as F = ε0AV²/(2d²). The pressure on each plate is F/A = ε0E²/2, which is the same as the energy density of the field. This link comes back in the energy chapter.
Using the full field E = σ/ε0 for this force is a common mistake. It gives a result that is twice too large, because a plate does not push on itself.
Inserting a conducting slab
Suppose a thin metal slab of thickness t is placed between the plates, parallel to them and not touching either. Charges are induced on its faces so that the field inside the metal is zero. The field exists only in the remaining gap, d − t.
V = E(d − t) = Q(d − t)/(ε0A)
C = ε0A/(d − t)
The result does not depend on where the slab sits. Only its thickness matters. A slab with t = d/2 doubles the capacitance. Treating the slab as two capacitors in series gives the same answer, because the gaps above and below it add to d − t.
Worked example 2: a slab and the plate separation
A capacitor has A = 0.02 m² and d = 4 mm. A copper sheet 1 mm thick is slid into the gap.
Before: C₀ = (8.85 × 10⁻¹² × 0.02)/(4 × 10⁻³) = 44.25 pF.
After: C = (8.85 × 10⁻¹² × 0.02)/(3 × 10⁻³) = 59 pF.
The ratio is C/C₀ = d/(d − t) = 4/3, which agrees with the numbers.
Plates with unequal charges
Real problems sometimes give the plates different charges, for example +Q₁ and −Q₂ or +Q₁ and +Q₂. The capacitance formula still holds, but the charge in C = Q/V is the magnitude of the charge that moves from one plate to the other, which is the difference in charge between the plates divided by two. For plates carrying charges Q₁ and Q₂, the facing charges are (Q₁ − Q₂)/2 on the inner face of plate 1, and the outer faces each carry (Q₁ + Q₂)/2. The potential difference between the plates is:
V = (Q₁ − Q₂)d/(2ε0A)
Each outer face carries half of the total charge, and the field outside is (Q₁ + Q₂)/(2ε0A). This check is a useful way to catch errors: the field in the gap is the difference-based value, while the field outside depends on the total.
Common errors
- Using σ/(2ε0) for the field between the plates. That is the value for a single sheet. The gap has σ/ε0.
- Forgetting that C does not change when Q or V changes. Only A, d and the medium change C.
- Mixing units: area in cm² or gap in mm without converting to m.
- Applying C = ε0A/d to plates that are far apart relative to their size. The uniform-field assumption fails and the actual capacitance is larger than the formula predicts, because of fringing.
- Using the total field when finding the force on one plate.
Exercise
A parallel-plate air capacitor has plates of area 0.05 m² separated by 2 mm. It is charged to 200 V and left connected to nothing. (a) Find C. (b) Find the charge on each plate. (c) Find the field in the gap. (d) Find the force of attraction between the plates. Use ε0 = 8.85 × 10⁻¹² F m⁻¹.
Show answer
(a) C = ε0A/d = (8.85 × 10⁻¹² × 0.05)/(2 × 10⁻³) = 2.21 × 10⁻¹⁰ F, about 221 pF. (b) Q = CV = 2.21 × 10⁻¹⁰ × 200 = 4.43 × 10⁻⁸ C. (c) E = V/d = 200/(2 × 10⁻³) = 1.0 × 10⁵ V/m. (d) F = Q²/(2ε0A) = (4.43 × 10⁻⁸)²/(2 × 8.85 × 10⁻¹² × 0.05) = 1.96 × 10⁻¹⁵/(8.85 × 10⁻¹³) ≈ 2.2 × 10⁻³ N. Check with F = ε0AV²/(2d²) = 8.85 × 10⁻¹² × 0.05 × 40000/(2 × 4 × 10⁻⁶) = 2.2 × 10⁻³ N.
Exercise
A parallel-plate capacitor has capacitance C₀. A metal slab of thickness d/3 is inserted between its plates, where d is the original separation. What is the new capacitance, and does it depend on the slab's position in the gap?
Show answer
The effective gap becomes d − d/3 = 2d/3, so C = ε0A/(2d/3) = 3C₀/2 = 1.5 C₀. It does not depend on the slab's position, because the field is zero inside the metal and only the total thickness of the remaining gap sets the potential difference.