Sub topic 16
Effect of non-ideal meters on measurements
This chapter assumes you know how to convert a galvanometer into an ammeter or voltmeter, and that you can reduce series and parallel resistor networks.
Ideal versus real meters
An ideal ammeter has zero resistance, so it does not change the current it measures. An ideal voltmeter has infinite resistance, so it draws no current. Real meters fall short of both. Every real meter changes the circuit it is connected to, so its reading differs from the value the circuit had before the meter was added.
- An ammeter is connected in series and adds its resistance R_A to that branch.
- A voltmeter is connected in parallel and lowers the resistance between the two points it touches.
Worked effects
A 10 V cell with negligible internal resistance drives a 100 Ω resistor. The true current is 0.100 A. An ammeter with R_A = 5 Ω reads 10/105 ≈ 0.0952 A, an error of about 4.8%.
Now two 1 kΩ resistors in series across 10 V. The true potential difference across the second resistor is 5 V. A voltmeter of resistance 1 kΩ across it gives a parallel combination of 500 Ω. The voltmeter reads 10 × 500/1500 ≈ 3.33 V.
Measuring R by V/I
To find R as V/I, there are two possible connections.
| Connection | Voltmeter is across | Ammeter reads | Value you calculate | Use when |
|---|---|---|---|---|
| A | Resistor and ammeter | Current through R | R + R_A | R is large compared with R_A |
| B | Resistor only | Current through R and voltmeter | R·R_V/(R + R_V) | R is small compared with R_V |
In connection A the error comes from the ammeter's resistance, so the calculated value is too large. In connection B the error comes from the current that leaks through the voltmeter, so the calculated value is too small.
Checking the numbers in code
def connection_a(R, R_A):
# Voltmeter spans resistor and ammeter
return R + R_A
def connection_b(R, R_V):
# Ammeter also carries the voltmeter current
return R * R_V / (R + R_V)
def divider_reading(E, R1, R2, R_V):
# Voltmeter of resistance R_V across R2 in a series divider
r_par = R2 * R_V / (R2 + R_V)
return E * r_par / (R1 + r_par)
print(connection_a(100.0, 1.0)) # 101.0
print(connection_b(100.0, 10000.0)) # about 99.01
print(divider_reading(10.0, 1e3, 1e3, 1e3)) # about 3.33Common errors
- Treating a voltmeter as ideal when its resistance is close to the resistance it is connected across.
- Forgetting that a lower circuit resistance also changes the current drawn from a cell with internal resistance.
- Applying the wrong correction. Choose connection A or B based on the size of R relative to the meter resistances, then correct as in the table.
Exercise
A 50 Ω resistor is measured with connection B. The voltmeter has resistance 450 Ω. What value of R does the calculation V/I give?
Show answer
V/I equals the parallel combination of 50 Ω and 450 Ω. That is 50 × 450 / (50 + 450) = 22500/500 = 45 Ω. The result is 10% too low because the voltmeter takes some of the current.