Sub topic 7
Sources, loads and the closed circuit
This chapter assumes you know charge, current as the rate of charge flow, and voltage as energy per unit charge. It also assumes you can read the polarity marks that show which terminal is higher in potential.
What a source and a load do
A source raises the energy of charge. A battery does this chemically and a generator does it mechanically. Each coulomb that passes through the source from its negative terminal to its positive terminal gains energy. The source does not create charge. The charge was already in the wires.
A load is any element that takes energy from the charge passing through it. A lamp turns it into light and heat. A motor turns it into motion. A resistor turns it into heat. Charge enters the load at the higher potential and leaves at the lower potential.
The source and the load therefore play opposite roles. The source lifts charge "uphill" in energy, and the load lets it fall back down.
Why the path must be closed
Current needs a complete loop. Charge cannot pile up at one point, because the charge that leaves the source must return to it. If you cut the loop anywhere, the current stops everywhere in that loop. This is an open circuit. The voltage across the gap is still present, but no sustained current flows.
A direct connection with almost no resistance across a source is a short circuit. The current becomes very large and can damage the source or the wires.
| State | Path | Current | Voltage across the break or element |
|---|---|---|---|
| Closed circuit | Complete loop through the load | Set by the source and the load | Shared across the load |
| Open circuit | Loop broken | Zero | Full source voltage appears across the gap |
| Short circuit | Near-zero resistance across the source | Very large | Near zero across the short |
Following the energy around the loop
Pick a single coulomb and follow it around the loop. In the source it gains energy. In the load it gives that energy up. By the time it is back at the source's negative terminal, it has the same energy it started with.
The current is the same size at every point in a single series loop. The charge moving through the load is the same charge that moved through the source, at the same rate. The voltage rise across the source equals the voltage drop across the load. This is the basis of Kirchhoff's voltage law, which a later chapter develops.
A worked example
A 12 V battery drives a lamp whose resistance is 48 ohms. The next chapters explain resistance and Ohm's law in full. For now, use the relation I = V / R to find the current.
source_voltage_v = 12.0
load_resistance_ohm = 48.0
# One loop: the source's voltage rise is the load's voltage drop.
load_voltage_v = source_voltage_v
current_a = load_voltage_v / load_resistance_ohm
# The same current flows through both elements.
power_delivered_w = source_voltage_v * current_a
power_absorbed_w = load_voltage_v * current_a
print(f"Loop current: {current_a:.3f} A")
print(f"Power delivered by source: {power_delivered_w:.2f} W")
print(f"Power absorbed by load: {power_absorbed_w:.2f} W")The loop current is 0.250 A. The source delivers 3.00 W and the load absorbs 3.00 W, so the energy balances.
Common errors
- Thinking the load "uses up" current. The current leaving the load equals the current entering it. The load uses up energy, not charge.
- Treating an open circuit as having no voltage. The source voltage is still present across the gap. Only the current is zero.
- Assuming a source always supplies the same current. An ideal voltage source holds its voltage fixed. The current depends on the load connected to it.
- Reading the source's terminals the wrong way. Current leaves the positive terminal of a source that is delivering power, and it enters the positive terminal of a load that is absorbing power.
Exercise
A 6 V source is connected to a 20 ohm load in a closed loop. What current flows through the source, and what happens to the current if the wire to the load is cut?
Show answer
The current is I = V / R = 6 / 20 = 0.3 A, and the same 0.3 A flows through the source and the load. If the wire is cut, the loop is open, so the current drops to zero everywhere in the loop. The 6 V still appears across the gap.