Sub topic 11
Measuring Current and Voltage with Meters
This chapter assumes you know the definitions of current (charge per unit time) and voltage (energy per unit charge), Ohm's law, and the idea of a closed circuit. It also assumes you are comfortable with SI prefixes such as milli and mega. The chapter covers how to connect an ammeter and a voltmeter, why each connection is correct, and how a real meter changes the circuit it measures.
What a meter actually does
A meter is a small circuit that you add to the circuit under test. Current and voltage are different kinds of quantity, so the two meters connect differently.
- Current is a flow through a path. To measure it, the meter must sit in the path so that all of that current passes through it.
- Voltage is a difference between two points. To measure it, the meter must touch both points and leave the path alone.
This gives the two rules the rest of the chapter builds on:
- An ammeter goes in series with the element whose current you want.
- A voltmeter goes in parallel with the element whose voltage you want.
Two elements are in series when the same current must flow through both. Two elements are in parallel when both are connected across the same pair of nodes, so they share the same voltage.
Connecting an ammeter
To measure the current in a resistor, you break the circuit at one point and insert the ammeter into the gap. Current that used to flow directly from wire to resistor now flows from wire to ammeter to resistor. Because the circuit is a single closed path, the same current passes through every element in series, so the ammeter reads the resistor's current.
Ammeter polarity matters for the sign of the reading. Most meters have a red (positive) terminal and a black (common) terminal. Current entering the red terminal and leaving the black terminal reads positive. This is the same idea as a reference direction: the meter's terminals define the direction for which a positive number means flow.
The ideal ammeter
An ideal ammeter has zero resistance, so it drops zero volts across itself and does not change the circuit. A real ammeter has a small resistance, called its burden resistance. That resistance adds to the circuit's total resistance and lowers the current slightly.
The mistake that blows fuses
Never connect an ammeter in parallel across a source or a component. Its resistance is tiny, so Ohm's law (I = V/R) predicts a very large current. A meter set to measure current, placed across a 12 V supply with a 0.1 Ω internal resistance, would try to carry about 120 A. At best the meter's fuse blows. At worst the meter, the leads, or the supply is damaged.
Connecting a voltmeter
To measure the voltage across a resistor, leave the circuit intact and touch the two probes to the two ends of the resistor. The meter now forms a second path between those two nodes. Current in the original circuit is almost unchanged, because the voltmeter draws very little.
The polarity convention is the same as for other voltage references. The meter reads positive when the red probe is at a higher potential than the black probe. If you swap the probes, the magnitude stays the same and the sign flips. A negative reading is useful information, since it tells you the node you assumed was higher is actually lower.
You can also measure a voltage relative to a reference node. Put the black probe on the reference (often called ground) and move the red probe to different nodes. Each reading is that node's voltage with respect to the reference. The voltage across an element is then the difference between the two node readings.
The ideal voltmeter
An ideal voltmeter has infinite resistance and draws no current. A real voltmeter has a large but finite input resistance, commonly 1 MΩ to 10 MΩ for a handheld digital meter. A small current flows through it, which can disturb the circuit.
Summary of the two connections
| Property | Ammeter | Voltmeter |
|---|---|---|
| Measures | Current through a branch | Voltage between two nodes |
| Connection | In series, with the circuit opened | In parallel, circuit left intact |
| Ideal internal resistance | 0 Ω | Infinite |
| Real internal resistance | Small (milliohms to a few ohms) | Large (about 1 MΩ to 10 MΩ or more) |
| Error if wrong | Placed in parallel: large current, blown fuse | Placed in series: almost no current flows, circuit stops working |
| Main loading effect | Adds series resistance, lowers current | Adds a parallel path, lowers voltage |
The voltmeter error row is worth understanding. If you put a voltmeter in series with a load, its huge resistance dominates the loop. Almost no current flows, so the load gets almost no voltage. The meter, however, reads nearly the full source voltage, because nearly all the voltage drops across the meter itself. This can mislead you into thinking the circuit is fine when it is not working.
Meter loading: how the measurement changes the circuit
A real meter has finite internal resistance, so connecting it changes the quantity you are trying to measure. This is called loading. The reading is the value of the modified circuit, not the original one.
- An ammeter with resistance RA in a loop with source voltage V and resistance R reads I = V / (R + RA). The true current without the meter is V / R. The reading is low by a factor R / (R + R_A).
- A voltmeter with input resistance RV across a resistor R replaces R with the parallel combination R·RV / (R + R_V). This is always smaller than R, so the voltage across that part of the circuit drops.
Loading is small when the meter is chosen well for the circuit:
- For an ammeter, R_A should be much smaller than the circuit resistance in the loop.
- For a voltmeter, R_V should be much larger than the resistance across which you measure.
Loading becomes serious in high-resistance circuits. A 10 MΩ voltmeter is a poor choice across a 5 MΩ resistor, because it cuts the resistance seen at that point by about a third.
Computing the loading error
The program below models two cases. In the first, an ammeter with 1 Ω resistance measures a 100 Ω loop on a 5 V source. In the second, a 10 MΩ voltmeter measures the lower resistor of a divider made of two 100 kΩ resistors on a 10 V source.
# Ammeter loading: a 5 V source drives a 100 ohm resistor.
v_source = 5.0
r_load = 100.0
r_ammeter = 1.0
i_true = v_source / r_load
i_measured = v_source / (r_load + r_ammeter)
i_error_pct = (i_measured - i_true) / i_true * 100.0
print(f"True current: {i_true * 1000:.2f} mA")
print(f"Measured current: {i_measured * 1000:.2f} mA")
print(f"Error: {i_error_pct:.2f} %")
# Voltmeter loading: 10 V across two 100 kilohm resistors in series.
v_supply = 10.0
r1 = 100e3
r2 = 100e3
r_voltmeter = 10e6
v_true = v_supply * r2 / (r1 + r2)
r2_loaded = r2 * r_voltmeter / (r2 + r_voltmeter) # R2 in parallel with the meter
v_measured = v_supply * r2_loaded / (r1 + r2_loaded)
v_error_pct = (v_measured - v_true) / v_true * 100.0
print(f"True voltage: {v_true:.3f} V")
print(f"Measured voltage: {v_measured:.3f} V")
print(f"Error: {v_error_pct:.2f} %")The ammeter reads 49.50 mA instead of 50.00 mA, an error of about -0.99 %. The voltmeter reads 4.975 V instead of 5.000 V, an error of about -0.50 %. Both errors are negative, because each meter adds a path that lowers what you measure. Both are small here only because the meters were well matched to the circuit.
Choosing a method to find current
You do not always have to break the circuit to find a current. There are two common approaches.
- Insert an ammeter in series. This reads the current directly, but you must open the circuit and accept the burden resistance.
- Measure the voltage across a known resistor and use Ohm's law. If a 10 Ω resistor reads 0.35 V, the current is 0.35 / 10 = 0.035 A. This needs no circuit break and presents a high-resistance load to the circuit.
The second method depends on the resistor's true value. Resistors have a tolerance, commonly 1 % to 5 %, so the computed current inherits that uncertainty. Also, a resistor that heats up changes its value slightly, so a measurement taken at a large power level may drift.
Common errors checklist
- Wrong function selected. The dial is on current while the probes sit across a source. This causes a blown fuse.
- Probes swapped. The sign of the reading flips. This is correct behavior, so read the sign against your reference polarity.
- Forgetting the meter is part of the circuit. For high-resistance nodes or low-resistance loops, check the loading estimate before trusting the number.
- Wrong range. On a manual-range meter, too low a range can overload the input. Start at the highest range and step down.
- Measuring AC with a DC setting. A DC voltmeter on an alternating signal may read near zero even though the signal is large. The next chapters in the sequence cover how DC and AC quantities differ.
Exercise
A 12 V source drives a 60 Ω resistor. You want to measure the resistor's current with an ammeter that has 0.5 Ω resistance. (a) Where do you connect the ammeter? (b) What current does it display? (c) By what percentage is the reading low?
Show answer
(a) In series with the resistor, with the circuit opened at one point so the full loop current passes through the meter. (b) I = 12 / (60 + 0.5) = 12 / 60.5 = 0.1983 A, which is about 198.3 mA. (c) The true current is 12 / 60 = 0.2000 A, so the reading is low by (0.2000 - 0.1983) / 0.2000 = 0.83 %.
Exercise
A voltmeter with 1 MΩ input resistance measures the voltage across the lower resistor of a divider. The divider uses two 1 MΩ resistors on a 9 V source. What does the voltmeter read, and why does it differ from the unloaded value?
Show answer
The unloaded voltage is 9 × 1/(1 + 1) = 4.5 V. The meter's 1 MΩ is in parallel with the lower 1 MΩ resistor, giving 0.5 MΩ. The loaded voltage is 9 × 0.5 / (1 + 0.5) = 3.0 V. The reading is 1.5 V low because the meter's resistance equals the resistance being measured, so it halves that resistance and shifts the divider ratio. A meter with an input resistance of 10 MΩ or more would be a better choice.
Exercise
A technician places a voltmeter in series with a lamp in a working circuit, instead of across it. The lamp goes dark, yet the meter reads almost the full source voltage. Explain both observations.
Show answer
The voltmeter's very large input resistance is now in the single loop with the lamp, so the loop current drops to a tiny value. The lamp, which needs ordinary current to glow, goes dark. Voltages in a series loop divide in proportion to resistance, so nearly all of the source voltage drops across the meter, and the lamp gets almost none. The meter therefore reads close to the source voltage.