Sub topic 15
Moving coil galvanometer and its conversion to ammeter and voltmeter
This chapter assumes you know the torque on a current loop, τ = NIAB sin θ, and the idea of a magnetic dipole moment. It also assumes you can handle series and parallel resistors and Ohm's law. The galvanometer is the main practical use of that torque.
What a galvanometer does
A moving coil galvanometer is an instrument that detects small currents. Its pointer deflects by an angle proportional to the current. On its own it can only handle currents of a few milliamperes or less. Adding a resistor turns it into an ammeter (large currents) or a voltmeter (potential differences).
Construction
The parts are:
- A rectangular coil of N turns and area A, wound on a light aluminium frame.
- Curved (concave) pole pieces of a permanent magnet, with a fixed soft-iron cylinder inside the coil.
- A phosphor-bronze suspension or hairspring that gives a restoring torque.
- A pointer attached to the coil, moving over a scale.
The soft-iron core and the concave poles make the field radial. At every position of the coil, the field lines lie in the plane of the coil. The two vertical sides always cut the field at 90° to their length, and the magnitude of B is the same across the gap.
Working principle
When current I flows, the two vertical sides feel equal and opposite forces F = NIlB. These forces make a couple. Because the field is radial, the angle between the coil's normal and B is always 90°, so sin θ = 1 for every deflection.
Deflecting torque:
τ = NIAB
The spring twists as the coil turns through an angle φ. Its restoring torque is kφ, where k is the torque per unit twist, the torsional constant. The coil settles where the two torques are equal:
NIAB = kφ, so φ = (NAB/k) I
The deflection is proportional to the current, so the scale is uniform and linear. Without the radial field, the torque would depend on sin θ and the scale would be cramped and non-linear.
Sensitivity
Sensitivity tells you how much deflection you get for a given input.
- Current sensitivity: φ/I = NAB/k, in radians per ampere (or divisions per ampere).
- Voltage sensitivity: φ/V = NAB/(kR), where R is the coil resistance and V = IR.
To raise current sensitivity, increase N, A or B, or reduce k (a weaker spring).
Why doubling N does not help voltage sensitivity
If you double N, the current sensitivity doubles. But the coil now has twice the wire, so its resistance R roughly doubles too. The ratio NAB/(kR) therefore stays about the same. This is a standard NEET trap. Voltage sensitivity rises only if you increase A, B, or lower k, without a matching rise in R.
| Change | Current sensitivity | Voltage sensitivity |
|---|---|---|
| N doubled | doubles | unchanged (R also doubles) |
| B doubled | doubles | doubles |
| Spring constant k doubled | halves | halves |
Full-scale current and the need for conversion
Let G be the galvanometer's resistance and Ig its full-scale current, the current that gives maximum deflection. The voltage across it at full scale is Ig G. It is tiny. For example, G = 50 Ω and I_g = 2 mA give only 0.1 V. To measure larger currents or voltages, you must stop the extra current or voltage from passing through the coil.
Converting to an ammeter: a shunt in parallel
An ammeter measures current and sits in series in the circuit. A small resistance S (the shunt) is connected in parallel with the galvanometer. Most of the current bypasses the coil.
To read up to a total current I, the coil carries Ig and the shunt carries I − Ig. Both have the same potential difference:
Ig G = (I − Ig) S
S = Ig G / (I − Ig)
The resulting ammeter resistance is
R_A = G S / (G + S)
This is smaller than both G and S. An ideal ammeter has zero resistance, so it does not change the current it measures. A good ammeter therefore needs a very small shunt.
Converting to a voltmeter: a resistor in series
A voltmeter measures potential difference and is connected in parallel across the component. A large resistance R is connected in series with the galvanometer, so that the full-scale current I_g flows when the voltage is V:
V = I_g (G + R)
R = V/I_g − G
The voltmeter resistance is RV = G + R = V/Ig. An ideal voltmeter has infinite resistance, so it draws no current from the circuit. A good voltmeter has a very large resistance.
Worked example in Python
Take G = 50 Ω and I_g = 2 mA. We want a 0–5 A ammeter and a 0–10 V voltmeter.
def shunt(G, Ig, I):
"""Shunt resistance for an ammeter of range I."""
return Ig * G / (I - Ig)
def series_resistance(G, Ig, V):
"""Series resistance for a voltmeter of range V."""
return V / Ig - G
def parallel(a, b):
return a * b / (a + b)
G = 50.0 # ohm
Ig = 2e-3 # ampere
S = shunt(G, Ig, 5.0)
R = series_resistance(G, Ig, 10.0)
print("Shunt S =", round(S, 5), "ohm") # 0.02001
print("Ammeter resistance =", round(parallel(G, S), 5)) # 0.02
print("Series R =", round(R, 1), "ohm") # 4950.0
print("Voltmeter resistance =", round(G + R, 1), "ohm") # 5000.0By hand: S = (0.002 × 50)/(5 − 0.002) = 0.1/4.998 ≈ 0.02 Ω. R = 10/0.002 − 50 = 4950 Ω. The ammeter's resistance is about V_g/I = 0.1/5 = 0.02 Ω, and the voltmeter's is 10/0.002 = 5000 Ω.
Effect of the meters on the circuit
Real meters change the circuit slightly.
- An ammeter adds its resistance RA in series, so the current drops a little. The reading is accurate when RA is much smaller than the circuit resistance.
- A voltmeter in parallel with a resistor R lowers the combined resistance to R RV/(R + RV). It reads accurately when R_V is much greater than R.
For example, a 5000 Ω voltmeter across a 5000 Ω resistor halves the resistance of that branch to 2500 Ω. The reading will be wrong. The same voltmeter across a 10 Ω resistor makes a negligible error.
Common errors
- Putting the shunt in series, or the high resistance in parallel. The ammeter shunt is always parallel and the voltmeter resistor is always series.
- Using I instead of I − I_g in the shunt formula. The shunt carries only the part of the current that the coil does not.
- Forgetting to subtract G when finding the series resistance. The formula is V/Ig − G, not V/Ig.
- Believing that more turns always raise voltage sensitivity. They also raise R.
- Thinking a larger range means a larger ammeter resistance. A larger range needs a smaller shunt, so the ammeter resistance gets smaller.
- Treating the radial field as optional. It is what keeps the torque at NIAB and the scale linear.
Exercises
Exercise
A galvanometer has resistance 100 Ω and shows full-scale deflection for 1 mA. Find the shunt needed to convert it to an ammeter of range 0–1 A, and the series resistance needed to convert it to a voltmeter of range 0–5 V.
Show answer
Shunt: S = Ig G/(I − Ig) = (0.001 × 100)/(1 − 0.001) = 0.1/0.999 ≈ 0.1 Ω, connected in parallel. Series resistance: R = V/I_g − G = 5/0.001 − 100 = 5000 − 100 = 4900 Ω, connected in series.
Exercise
A galvanometer's number of turns is doubled with the same wire size, coil area, field and spring. What happens to its current sensitivity and its voltage sensitivity?
Show answer
Current sensitivity NAB/k doubles because N doubles. The coil's resistance R also doubles because the wire length doubles. Voltage sensitivity NAB/(kR) therefore stays unchanged.
Exercise
Why must the field in a moving coil galvanometer be radial, and what does this give?
Show answer
A radial field keeps the plane of the coil parallel to B at every deflection, so sin θ = 1 and the torque is always NIAB. With the spring torque kφ, this gives φ = (NAB/k) I, so the deflection is proportional to the current and the scale is uniform.