Sub topic 3
Susceptibility and Permeability of Magnetic Materials
Assume you know magnetic field, vectors, torque, and basic electric dipoles. The key quantities are magnetization, susceptibility, and permeability.
Susceptibility and permeability
Magnetization M is the magnetic dipole moment per unit volume. Magnetic intensity H is the applied magnetizing field. For a linear material,
M = χH
where χ is magnetic susceptibility. It has no unit.
The magnetic flux density is
B = μ₀(H + M) = μ₀(1 + χ)H
Relative permeability is
μᵣ = 1 + χ
Thus,
B = μ₀μᵣH
A large positive χ means strong magnetization in the direction of the applied field.
Diamagnetic, paramagnetic and ferromagnetic materials
| Material | Susceptibility | Behaviour | Example |
|---|---|---|---|
| Diamagnetic | Small and negative | Weakly repelled; `μᵣ < 1` | Copper, bismuth |
| Paramagnetic | Small and positive | Weakly attracted; `μᵣ > 1` | Aluminium, platinum |
| Ferromagnetic | Very large and positive | Strongly attracted; forms domains | Iron, cobalt |
Diamagnetic magnetization opposes the applied field. Paramagnetic atoms have permanent magnetic moments that partly align with the field. Ferromagnetic domains can remain aligned even after the field is removed.
> callout note > Susceptibility describes how easily a material becomes magnetized. Permeability describes how much magnetic flux density results from a given H.
Curie law and Curie-Weiss law
For a paramagnet,
χ = C/T
where C is the Curie constant and T is absolute temperature. Therefore, doubling T halves χ.
Above the Curie temperature T꜀, a ferromagnet often follows the Curie-Weiss law:
χ = C/(T - T꜀)
At and below T꜀, long-range ferromagnetic order can exist. Above T꜀, thermal motion destroys this order.
def curie_susceptibility(C, T):
return C / T
C = 1.0
print(curie_susceptibility(C, 300))
print(curie_susceptibility(C, 600))Hysteresis and magnetic materials
When a ferromagnet is magnetized and then demagnetized, B does not follow the same path. This lag is called hysteresis.
Retentivity is the residual magnetism when H becomes zero. Coercivity is the reverse field needed to make B zero. The loop area represents energy loss per unit volume in one cycle.
Permanent magnets need high retentivity and high coercivity. Electromagnets need high permeability and low coercivity. Transformer cores need high permeability and a narrow hysteresis loop, which reduces energy loss.
Exercise
A material has χ = 4. What is its relative permeability?
Show answer
μᵣ = 1 + χ = 5.