Sub topic 13
Hysteresis loop, retentivity, coercivity and energy loss
This chapter assumes you know the relations B = μ0(H + M), susceptibility χ and relative permeability μr, and the difference between ferromagnetic, paramagnetic and diamagnetic materials. Hysteresis is a property of ferromagnets only.
What the loop shows
Place an unmagnetized ferromagnetic rod inside a solenoid. The current in the solenoid sets the magnetic intensity H. The material's response is the flux density B inside it. Plot B against H as you change the current.
- Increase H from zero. B rises along the virgin curve until it saturates. All the magnetic domains (small regions of aligned atomic moments) now point along the field.
- Reduce H back to zero. B does not return to zero along the same path.
- Reverse the current and increase H in the opposite direction. B falls to zero only at a certain negative H, then saturates in the opposite sense.
- Bring H back to zero and then to positive values. The curve closes into a loop.
The word hysteresis means "lagging behind". B lags behind H because domain walls do not move back freely once they have moved.
Retentivity and coercivity
- Retentivity (remanence) is the value of B left in the material when H has been reduced to zero. It measures how strongly the material stays magnetized.
- Coercivity is the reverse H needed to bring B to zero. It measures how hard it is to demagnetize the material.
| Property | Where on the loop | Meaning |
|---|---|---|
| Retentivity | B-axis intercept at H = 0 | Magnetism left after the field is removed |
| Coercivity | H-axis intercept at B = 0 | Reverse field needed to erase it |
| Loop area | Enclosed area | Energy lost per cycle per unit volume |
Energy loss
When the material is taken around one full loop, the energy dissipated as heat per unit volume equals the area enclosed by the B–H loop. In SI units, B is in tesla and H in A/m, so the area is in T·A/m, which equals J/m³. The loss per second is this value multiplied by the frequency of the cycle.
A wide loop means a large loss. A narrow loop means a small loss.
def hysteresis_loss_power(loop_area, volume, frequency):
# loop_area in J/m^3 per cycle, volume in m^3, frequency in Hz
return loop_area * volume * frequency # watts
# Soft iron core in a transformer: 50 Hz, 0.002 m^3, loop area 300 J/m^3
print(hysteresis_loss_power(300, 0.002, 50)) # 30.0 WSoft and hard materials
The shape of the loop decides what a material is good for.
| Feature | Soft iron | Steel, alnico |
|---|---|---|
| Retentivity | High | High |
| Coercivity | Low | High |
| Loop | Narrow and tall | Wide and fat |
| Loop area (energy loss) | Small | Large |
| Permeability | High | Lower |
| Use | Electromagnet cores, transformer cores, motors | Permanent magnets |
Soft iron magnetizes and demagnetizes easily, so its loss per cycle is small. That suits cores carrying alternating current. Steel resists demagnetization, so it keeps its magnetism for a long time. That suits permanent magnets.
Common NEET points
- The area of the loop, not its height, gives the energy loss.
- Retentivity is read on the B-axis. Coercivity is read on the H-axis.
- A transformer core needs a small loop area, so hysteresis loss stays low at 50 Hz.
- Demagnetizing a magnet is done by placing it in a solenoid carrying alternating current and slowly reducing the current to zero, which takes it around ever smaller loops.
Exercise
A ferromagnetic core is taken through 60 complete cycles per second. The B–H loop has an area of 250 J/m³ and the core volume is 0.004 m³. Find the power lost as heat. Then say whether a material with a wider loop would be better or worse for this core.
Show answer
Energy lost per cycle = 250 × 0.004 = 1.0 J. Power = 1.0 J × 60 per second = 60 W. A wider loop means a larger area, so more loss. It would be worse for this core. A narrow loop, as in soft iron, is better.
Exercise
Two rods have the same retentivity. Rod P has coercivity 50 A/m and rod Q has coercivity 5000 A/m. Which is better for a permanent magnet, and why?
Show answer
Rod Q. Its high coercivity means a large reverse field is needed to demagnetize it, so it keeps its magnetism against stray fields and knocks. Rod P loses its magnetism easily.